Customization: | Available |
---|---|
After-sales Service: | Enginner Overseas |
Warranty: | 12 Month |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
X-ray sensor | L-shape photodiode array detector (multi-energy), 16BIT depth. |
Displayer | 1.57 MM high resolution liquid crystal display. |
Magnifying glass | Partial amplification, real-time dynamic amplification. |
Image magnification | It can be amplified 2-64 times in real time. |
Edge enhancement | The outline of object is clearer. |
Super enhancement | The detail of image is clearer. |
Image brightness | Increase/decrease the brightness of image. |
Image storage | Image can be saved and processed in real time. It can store 1 million images. |
Image restoration | Image display returns to the original state of the belt stopped. |
Image pull-back | Display the first 20 images, and the pullback image can be performed image processing. |
Multi-energy and color | Organic is shown in orange, inorganic is shown in blue, and mixture is shown in green. |
High/low penetration | Improve the contrast of the bright areas in the image and make the area clearer. |
Fault self-diagnosis | Automatically judge the fault, and give a prompt information for maintaining. |
One-key ON/FF | Click the start button to turn on the device, turn off the key once to turn off the device. |
Automatic design | Device can automatically induct objects, and if it has something on it, machine will start automatically. If it has nothing on it, device is still. |
Double lead curtain | Lead curtain adopt new pressure membrane technology to prevent people from being exposed to lead and being polluted. |
Scanning direction | Bi-directional scanning can scan the object transmitted in any direction. |
Tunnel Size | 500(W) * 300(H) mm |
Speed of Conveyor | 0.22 m/s |
Rated Load | 160 kg |
Penetration | 43 mm steel plate |
Resolution | Single core copper wire with diameter of 0.078 mm |
Beam Direction | Bottom illumination |
Tube Current | 0.4 - 0.5 mA (adjustable) |
Tube Voltage | 100 ~ 160 kV |
Beam Divergence Angle | 60° |
Cooling/Working Period | Sealed oil cooling / 100% |
Safety of Film | ISO1600 film safety |
Single Dose of Checking | ≤1.9 μGy |
Leakage Dose Rate | <0.18 μGy/h |
Working Temp/Humidity | 0~45°C / 20%~95% (non-condensation) |
Storage Temp/Humidity | -20°C ~ 60°C / 20%~95% (non-condensation) |
Working Voltage | 220VAC (±10%) 50±3Hz |
Power Consumption | 0.5 kW (max) |
Noise | ≤54 dB |