Customization: | Available |
---|---|
After-sales Service: | Enginner Overseas |
Warranty: | 12 Month |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
X-ray sensor | L-shaped photodiode array detector (multi-energy), 16BITTdepth |
Displayer | 1.57 MM high-resolution liquid crystal display |
Magnifying glass | Partial amplification, real-time dynamic amplification |
Image magnification | Can be amplified 2-64 times in real time |
Edge enhancement | The outline of the object is clearer |
Super enhancement | The detail of the image is clearer |
Image brightness | Increase/decrease the brightness of the image |
High/low energy | Two kinds of energy switch, high energy displays metal, low energy displays non-metal |
Image storage | Images can be saved and processed in real time, storing up to 1 million images |
Image restoration | Image display returns to the original state when the belt stopped |
Image pull-back | Display the first 20 images, and the pullback image can be performed image processing |
Multi-energy and color | Organic is shown in orange, inorganic is shown in blue, and mixture is shown in green |
High/low penetration | Improve the contrast of the bright areas in the image and make the area clearer |
Scanning direction | Bi-directional scanning can scan the object transmitted in any direction |
Fault self-diagnosis | Automatically judge the fault and give prompt information for maintaining easily |
One-key ON/FF | Click the start button to turn on the device, turn off the key once to turn off the device |
Automatic design | Device can automatically induct objects, and if it has something on it, the machine will start automatically, or it is still |
Double lead curtain | Lead curtain adopt new pressure membrane technology to prevent people from being exposed to lead and being polluted |
Tunnel size | 1000(W)*1000(H)mm |
Speed of conveyor | 0.22m/s |
Rated load | 250kg |
Penetration | 38mm steel plate |
Resolution | Single core copper wire with diameter of 0.078mm |
Single dose of checking | ≤1.5 μGy |
Leakage dose | <0.2 μGy/h |
Beam direction | Top illumination |
Tube current | 0.4-1.2mA (adjustable) |
Tube voltage | 100-160kV |
Beam divergence angle | 80° |
Cooling/working period | Sealed oil cooling/100% |
Safety of film | ISO1600 film safety |
Working temp/ humidity | 0~45°C 20%~95% (non-condensation) |
Storage temp/ humidity | -20°C ~ 60°C / 20% ~ 95% (non-condensation) |
Working voltage | 220VAC(±10%) 50±3HZ |
Power consumption | 1.0 KW (max) |
Noise | ≤54dB |