Customization: | Available |
---|---|
Transport Package: | Carton Box |
Specification: | 40 pcs one box |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Introduction:
POWER SUPPLY |
Working frequency | with automatic frequency conversion function, 22KHZ |
Battery recharge | Fully recharge the battery in approximately 4-6 hours | |
Reset time | 0.5 seconds, automatically | |
Standby current | <50mA | |
Working voltage | dc 7 to 12 v | |
Power | Biggest 270mW | |
Save electricity |
250 MA The battery can work continuously more than 40 hours when fell to about 7 V, 9 V detection range won't change. |
|
Battery | Use one 9-volt standard or rechargeable battery | |
DIMENSIONS | Length | 29.5cm |
Width | 6.8cm | |
Thickness | 2cm | |
Total Weight | net weight 270 grams | |
ENVIRONMEN- TAL DATA | Operating temperature | -10ºC-65ºC |
OPERATION |
Power control | A sustained press of the button for one second will commence the machine's operation. |
Battery Installation | Slide open the battery cover, place the battery in the battery compartment ensuring the positive and negative symbols match. |
|
Status Indicators |
If the green LED light does not illuminate or if the detector emits unfamiliar audio signals, the detector is unstable and should be charged or the battery replaced. |
|
Applications |
1) Airport, station, wharfs electronic detection inspection. 2) Customs, public, security border and security departments' safety inspection. 3) Medicine, food quality inspection business system. 4) Timber inspection nails, important places, playground safety inspection. 5) Precious metals testing, such as gold and silver &artificial jewelry co, electronics factory. |
|
Metal Detection Indication |
In the event of metal detection, the device will provide an auditory and visual indication. To ensure consistent detection, continuous scanning is recommended |
|
Low battery voltage indication | Side the yellow indicator light will illuminate when the battery level is critically low. Prompt action is required to recharge or replace the battery. | |
Turning On |
Press the red on/off switch until it clicks and the green LED light illuminates, now the detector is ready for use |