Customization: | Available |
---|---|
After-sales Service: | Enginner Overseas |
Warranty: | 12 Month |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
X-ray sensor | L-shape photodiode array detector (multi-energy), 16BITdepth |
Displayer | 1.57 MM high resolution liquid crystal display |
Magnifying glass | Partial amplification, real-time dynamic amplification |
Image magnification | It can be amplified 2-64 times in real time |
Edge enhancement | The outline edge of the object is clearer |
Super enhancement | The detail of image is clearer |
Image brightness | Increase/decrease the brightness of image |
Image storage | Image can be saved and be processed in real time. It can store 1 million images. |
Image restoration | Image display returns to the original state when the belt stops. |
Image pull-back | Display the first 20 images, and the pullback image can be performed image processing. |
Multi-energy and color | Organic is shown in orange, inorganic is shown in blue, and mixture is shown in green. |
High/ low penetration | Improve the contrast of the bright areas in the image and make the area clearer. |
Fault self-diagnosis | Automatically judge the fault, and give the prompt information for maintaining easily. |
One-key ON/FF | Click the start button to turn on the device, turn off the key once to turn off the device. |
Automatic design | Device can automatically induct objects, and if it has something on it, machine will start automatically. If it has nothing on it, device is still. |
Double lead curtain | Lead curtain adopts new pressure membrane technology to prevent people from being exposed to lead and being polluted. |
Scanning direction | Bi-directional scanning can scan the object transmitted in any direction. |
Channel size | 650 (W) * 500 (H) mm |
Speed of conveyor | 0.22 m/s |
Rated load | 180 kg |
Penetration | 46 mm steel plate |
Resolution | Single core copper wire with diameter of 0.078 mm |
Single dose of checking | ≤0.88 µGy |
Leakage dose | <0.09 µGy/h |
Beam direction | Bottom illumination |
Tube current | 0.4-1.2 mA (adjustable) |
Tube voltage | 100-160 kV |
Beam divergence angle | 60° |
Cooling/working period | Sealed oil cooling/100% |
Safety of film | ISO1600 film safety |
Working temperature/humidity | 0~45°C 20%~95% (non-condensation) |
Storage temperature/humidity | -20°C~60°C / 20%~95% (non-condensation) |
Working voltage | 220VAC(±10%) 50±3HZ |
Power consumption | 1.0 KW (max) |
Noise | ≤55dBA |